General Electric AK-2-25 Manually Operated Air Circuit Breaker.

Part/Catalog Number: AK-2-25Original Manufacturer: General Electric (GE)Product Line: AKAmps: 600A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: RMS-9 LIVoltage: 600V MaxInterrupting Capacity: 25kAIC Description: The featured General Electric AK-2-25 is a 600A Frame, Manually Operated, Draw-out Style, Air Circuit Breaker. It was originally outfitted with EC-1 or EC-2 series electro-mechanical overloads, however, new trip unit models are available. […]

Read More… from General Electric AK-2-25 Manually Operated Air Circuit Breaker.

ABB 18006P10 115VAC/125VDC Spring Charging Motor for Advac

Manufacturer: ABBPart Number: 18006P10Breaker Type: All Advac Vacuum Circuit Breakers. Description: The ABB Model 50506 spring charging motor 18006P10 is rated 115VAC and 125VDC and is interchangeable in all stored energy operating mechanisms on ABB Advac Vacuum Circuit Breakers. […]

Read More… from ABB 18006P10 115VAC/125VDC Spring Charging Motor for Advac

FPE type 100H-2 4000A Manually Operated Fused Air Circuit Breaker.

Part/Catalog Number: 100H-2Original Manufacturer: FPE/Federal Pacific/Federal PioneerProduct Line: HAmps: 4000A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: AC-ProVoltage: 600V MaxInterrupting Capacity: 100kAIC @ 480V Description: The FPE 100H-2 is a 4000A Frame, Manually Operated, Draw-out Style, Fused Air Circuit Breaker. It was originally outfitted with a USD trip unit, however, new trip unit models are available. Although the […]

Read More… from FPE type 100H-2 4000A Manually Operated Fused Air Circuit Breaker.

FPE type 75H-3 3200A Manually Operated Fused Air Circuit Breaker.

Part/Catalog Number: 75H-3Original Manufacturer: FPE/Federal Pacific/Federal PioneerProduct Line: HAmps: 3200A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: USD LSIGVoltage: 600V MaxInterrupting Capacity: 75kAIC @ 480V Description: The FPE 75H-3 is a 3200A Frame, Manually Operated, Draw-out Style, Fused Air Circuit Breaker. It was originally outfitted with a USD trip unit, however, new trip unit models are available. Although […]

Read More… from FPE type 75H-3 3200A Manually Operated Fused Air Circuit Breaker.

FPE type 30HL-2 Manually Operated Fused Air Circuit Breaker.

Part/Catalog Number: 30HL-2Original Manufacturer: FPE/Federal Pacific/Federal PioneerProduct Line: HLAmps: 800A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: AC-ProVoltage: 600V MaxInterrupting Capacity: 200kAIC Description: The FPE 30HL-2 is a 800A Frame, Manually Operated, Draw-out Style, Fused Air Circuit Breaker. The 30HL-2 takes a maximum 1200A NEMA Class L fuses. It was originally outfitted with a USD trip unit, however, […]

Read More… from FPE type 30HL-2 Manually Operated Fused Air Circuit Breaker.

Medium Voltage Air Circuit Breaker List

ABB/ITE/BBC/Gould 15HK-1000 1200A Model 10 15HK-1000 3000A Model 10 15HK-1000 1200A Model 11 15HK-1000 2000A Model 11 15HK-1000 3000A Model 11 15HK-500 1200A 15HK-500 2000A 5HK-250 2000A 5HK-350 3000A Siemens / Allis Chalmers MA-250B 1200A MA-250C 1200A MA-250C 2000A MA-350C 2000A MC-500 2000A FC-500 1200A MA-250C1 1200A Federal Pacific / FPE DST-2-15-500 1200A DST-2-5-250 1200A […]

Read More… from Medium Voltage Air Circuit Breaker List