Siemens type 15-GMI-1000-1200 1200A Vacuum Circuit Breaker

Part/Catalog Number: 15-GMI-1000-1200Original Manufacturer: SiemensProduct Line: GMIAmps: 1200A FrameOperation: Electrically OperatedMounting: Draw-out Voltage: 15kV MaxInterrupting Capacity: 1000mVA Description: The Siemens 15-GMI-1000-1200 is rated for 1200A continuous current, 15kV, 1000mVA and was designed to fit into single high or two high Siemens GM/GMI Switchgear sections. 15-GMI-1000-1200 1200A Parts & Resources:– Charging Motors– Vacuum Bottles– Trip Coils– Close Coils– […]

Read More… from Siemens type 15-GMI-1000-1200 1200A Vacuum Circuit Breaker

Siemens type 15-GMI-500-1200 1200A Vacuum Circuit Breaker

Part/Catalog Number: 15-GMI-500-1200Original Manufacturer: SiemensProduct Line: GMIAmps: 1200A FrameOperation: Electrically OperatedMounting: Draw-out Voltage: 15kV MaxInterrupting Capacity: 500mVA Description: The Siemens 15-GMI-500-1200 is rated for 1200A continuous current, 15kV, 500mVA and was designed to fit into single high or two high Siemens GM/GMI Switchgear sections. 15-GMI-500-1200 1200A Parts & Resources:– Charging Motors– Vacuum Bottles– Trip Coils– Close Coils– […]

Read More… from Siemens type 15-GMI-500-1200 1200A Vacuum Circuit Breaker

ABB type 15GHK-500 1200A SF6 Gas Circuit Breaker

Part/Catalog Number: 15GHK-500 1200AOriginal Manufacturer: ABBProduct Line: GHKAmps: 1200A FrameOperation: Electrically OperatedMounting: Draw-out Voltage: 15kV MaxInterrupting Capacity: 500mVA Description: The 15GHK-500 1200A SF6 Gas circuit breaker was designed by ABB to be utilized as a generator rated breaker. The 15GHK-500 is rated 1200A, 15kV, 500mVA and is designed to be inserted into type HK II ANSI rated […]

Read More… from ABB type 15GHK-500 1200A SF6 Gas Circuit Breaker

Siemens type 15-FSV-1000-1200-77 1200A Vacuum Replacement Circuit Breaker

Part/Catalog Number: 15-FSV-1000-1200-77 Original Manufacturer: SiemensProduct Line: FSV/FCAmps: 1200A FrameOperation: Electrically OperatedMounting: Draw-out Voltage: 15kV MaxInterrupting Capacity: 1000mVA Description: The Siemens 15-FSV-1000-1200-77 was designed to directly replace the Siemens/Allis Chalmers type FC-1000 1200A Air Circuit Breaker. The 15-FSV-1000 is rated for 1200A continuous current, 15kV, 1000mVA. 15-FSV-1000 1200A Parts & Resources:– Charging Motors– Vacuum Bottles– Trip Coils– […]

Read More… from Siemens type 15-FSV-1000-1200-77 1200A Vacuum Replacement Circuit Breaker

Ground & Test Device List

General Electric Ground & Test Devices 3000A G&T for General Electric Powervac VB/VB1 Electrically Operated G&T for GE AM-13.8-750 1200A & 2000A Vertical Lift Switchgear G&T for GE AMH-4.76-250 1200A & 2000A Draw-out Switchgear. Ground & Test Device for GE AM-13.8-1000 3000A Vertical Lift Switchgear Ground & Test Device for GE AM-13.8-750 1200A & 2000A […]

Read More… from Ground & Test Device List

3000A Ground & Test Device for General Electric Powervac VB/VB1

Part/Catalog Number: PVV-3000 6-StudOriginal Manufacturer: General Electric (GE)Product Line: PowerVac VB/VB1Amps: 3000A Voltage: 5kV, 7.5kV & 15kV Description: The 3000A PowerVac Ground & Test Device, is a 6-Stud, Manually Operated G&T. It can be designed to be racked into a all 3000A GE PowerVac vacuum circuit breaker positions and provides the operator access to the cell side […]

Read More… from 3000A Ground & Test Device for General Electric Powervac VB/VB1

Electrically Operated Ground & Test Device for Siemens/Allis-Chalmers type MA-250/350 2000A Switchgear

Part/Catalog Number: MA-250/350 2000A 3-Stud EO Original Manufacturer: Siemens/Allis-ChalmersProduct Line: MAAmps: 2000AVoltage: 5kVOperation: Electrically Operated Description: This Siemens-Allis type MA-250/350 Ground & Test Device is a 2000A , 3-Stud, Electrically Operated (G&T) can be racked into any MA-250 or MA-350, 2000A air circuit breaker position and provides the operator access to the cell side primary disconnects to […]

Read More… from Electrically Operated Ground & Test Device for Siemens/Allis-Chalmers type MA-250/350 2000A Switchgear

Electrically Operated Ground & Test Device for Siemens/Allis-Chalmers type MA-250 1200A Switchgear

Part/Catalog Number: MA-250 1200A 3-Stud EO G&TOriginal Manufacturer: Siemens/Allis-ChalmersProduct Line: MAAmps: 1200AVoltage: 5kVOperation: Electrically Operated Description: This Siemens-Allis type MA-250 Ground & Test Device is a 1200A , 3-Stud, Electrically Operated (G&T) can be racked into any MA-250, 1200A air circuit breaker position and provides the operator access to the cell side primary disconnects to ground and […]

Read More… from Electrically Operated Ground & Test Device for Siemens/Allis-Chalmers type MA-250 1200A Switchgear

Electrically Operated Ground & Test Device for Siemens type GM/GMI Switchgear

Part/Catalog Number: GMI-EO-G&TOriginal Manufacturer: SiemensProduct Line: GM/GMIAmps: 1200, 2000 & 3000AVoltage: 5kV, 7.5kV & 15kVOperation: Electrically Operated Description: The GMI Electrically Operated Ground & Test Device, is a 3-Stud, Manually Operated (G&T). It can be designed to be racked into all Siemens GM/GMI vacuum circuit breaker positions and provides the operator access to the cell side primary […]

Read More… from Electrically Operated Ground & Test Device for Siemens type GM/GMI Switchgear