General Electric type THC1616SSE1C 1600A Electrically Operated Insulated Case Circuit Breaker.

Part/Catalog Number: THC1616SSE1COriginal Manufacturer: General Electric / GEProduct Line: Powerbreak I – THCAmps: 1600A FrameOperation: Electrically Operated – 120VACMounting: Draw-out Trip Unit: MicroVersaTrip RMS-9 LSIGVoltage: 600V MaxInterrupting Capacity: 100kAIC Description: The GE THC1616SSE1C is a 1600A Frame, Electrically Operated, Draw-out Style Insulated Case Circuit Breaker. It was originally outfitted with the MicroVersaTrip RMS-9 trip unit, however, new […]

Read More… from General Electric type THC1616SSE1C 1600A Electrically Operated Insulated Case Circuit Breaker.

General Electric type TP1616SSZE3 1600A Electrically Operated Insulated Case Circuit Breaker.

Part/Catalog Number: TP1616SSZE3Original Manufacturer: General Electric / GEProduct Line: Powerbreak I – TPAmps: 1600A FrameOperation: Electrically Operated – 125VDCMounting: Draw-out Trip Unit: MicroVersaTrip RMS-9 LSIGVoltage: 600V MaxInterrupting Capacity: 85kAIC Description: The GE TP1616SSZE3 is a 1600A Frame, Electrically Operated, Draw-out Style Insulated Case Circuit Breaker. It was originally outfitted with the MicroVersaTrip RMS-9 trip unit, however, new […]

Read More… from General Electric type TP1616SSZE3 1600A Electrically Operated Insulated Case Circuit Breaker.

General Electric type SSD30B330 3000A Manually Operated Insulated Case Circuit Breaker.

Part/Catalog Number: SSD30B330 MO/DOOriginal Manufacturer: General Electric / GEProduct Line: Powerbreak II – SHDAmps: 3000A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: MicroVersaTrip PM LSIGVoltage: 600V MaxInterrupting Capacity: 100kAIC Description: The GE SSD30B330 is a 3000A Frame, Manually Operated, Draw-out Style Insulated Case Circuit Breaker. It was originally outfitted with the MicroVersaTrip Plus or PM trip unit, however, […]

Read More… from General Electric type SSD30B330 3000A Manually Operated Insulated Case Circuit Breaker.

Westinghouse type SPB-100 2000A Electrically Operated Insulated Case Circuit Breaker.

Part/Catalog Number: SPB-100 2000A EO/DO Original Manufacturer: WestinghouseProduct Line: SPBAmps: 2000A FrameOperation: Electrically OperatedMounting: Draw-out Trip Unit: Pow-R-Trip 7 LIGVoltage: 600V MaxInterrupting Capacity: 100kAIC Description: The Westinghouse SPB-100 is a 2000A Frame, Electrically Operated, Draw-out Style, Insulated Case Circuit Breaker. It was originally outfitted with a Pow-R-Trip 7 series trip unit, however, new trip unit models are […]

Read More… from Westinghouse type SPB-100 2000A Electrically Operated Insulated Case Circuit Breaker.

Westinghouse type SPB-100 800A Manually Operated Insulated Case Circuit Breaker.

Part/Catalog Number: SPB-100 800A MO/DOOriginal Manufacturer: WestinghouseProduct Line: SPBAmps: 800A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: Digitrip RMS-510 SeriesVoltage: 600V MaxInterrupting Capacity: 100kAIC Description: The Westinghouse SPB-100 is a 800A Frame, Manually Operated, Draw-out Style, Insulated Case Circuit Breaker with Bell Alarm / Lockout. It was originally outfitted with a Digitrip series trip unit, however, new trip […]

Read More… from Westinghouse type SPB-100 800A Manually Operated Insulated Case Circuit Breaker.

Westinghouse type SPB-100 2500A Manually Operated Insulated Case Circuit Breaker.

Part/Catalog Number: SPB-100 2500A MO/DOOriginal Manufacturer: WestinghouseProduct Line: SPBAmps: 2500A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: Digitrip RMS-510 SeriesVoltage: 600V MaxInterrupting Capacity: 100kAIC Description: The Westinghouse SPB-100 is a 2500A Frame, Manually Operated, Draw-out Style, Insulated Case Circuit Breaker with Bell Alarm / Lockout. It was originally outfitted with a Digitrip series trip unit, however, new trip […]

Read More… from Westinghouse type SPB-100 2500A Manually Operated Insulated Case Circuit Breaker.

Westinghouse type SPB-100 4000A Manually Operated Insulated Case Circuit Breaker.

Part/Catalog Number: SPB-100 4000A MO/DOOriginal Manufacturer: WestinghouseProduct Line: SPBAmps: 4000A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: Digitrip RMS-810 SeriesVoltage: 600V MaxInterrupting Capacity: 100kAIC Description: The Westinghouse SPB-100 is a 4000A Frame, Manually Operated, Draw-out Style, Insulated Case Circuit Breaker. It was originally outfitted with a Digitrip series trip unit, however, new trip unit models are available. Although […]

Read More… from Westinghouse type SPB-100 4000A Manually Operated Insulated Case Circuit Breaker.

Westinghouse type SPB-100 1200A Manually Operated Insulated Case Circuit Breaker.

Part/Catalog Number: SPB-100 1200A MO/DOOriginal Manufacturer: WestinghouseProduct Line: SPBAmps: 1200A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: Digitrip RMS-510 SeriesVoltage: 600V MaxInterrupting Capacity: 100kAIC Description: The Westinghouse SPB-100 is a 1200A Frame, Manually Operated, Draw-out Style, Insulated Case Circuit Breaker with Bell Alarm / Lockout. It was originally outfitted with a Digitrip series trip unit, however, new trip […]

Read More… from Westinghouse type SPB-100 1200A Manually Operated Insulated Case Circuit Breaker.

Westinghouse type SPB-50 800A Electrically Operated Insulated Case Circuit Breaker.

Part/Catalog Number: SPB-50 800A EO/DO Original Manufacturer: WestinghouseProduct Line: SPBAmps: 800A FrameOperation: Electrically OperatedMounting: Draw-out Trip Unit: Pow-R-Trip 7 LIVoltage: 600V MaxInterrupting Capacity: 50kAIC Description: The Westinghouse SPB-50 is a 800A Frame, Electrically Operated, Draw-out Style, Insulated Case Circuit Breaker. It was originally outfitted with a Pow-R-Trip 7 series trip unit, however, new trip unit models are […]

Read More… from Westinghouse type SPB-50 800A Electrically Operated Insulated Case Circuit Breaker.

Westinghouse type SPB-65 1600A Electrically Operated Insulated Case Circuit Breaker.

Part/Catalog Number: SPB-65 1600A EO/DO Original Manufacturer: WestinghouseProduct Line: SPBAmps: 1600A FrameOperation: Electrically OperatedMounting: Draw-out Trip Unit: AC-Pro IIVoltage: 600V MaxInterrupting Capacity: 65kAIC Description: The Westinghouse SPB-65 is a 1600A Frame, Electrically Operated, Draw-out Style, Insulated Case Circuit Breaker. It was originally outfitted with a Digitrip series trip unit, however, new trip unit models are available. Although […]

Read More… from Westinghouse type SPB-65 1600A Electrically Operated Insulated Case Circuit Breaker.