ABB/BBC type LKE-8, 800AF Electrically Operated Air Circuit Breaker.

Part/Catalog Number: LKE-8Original Manufacturer: ABB/BBCProduct Line: LKAmps: 800A FrameOperation: Electrically OperatedMounting: Draw-out Trip Unit: AC-ProVoltage: 600V MaxInterrupting Capacity: 50kAIC Description: The LKE-8 is an 800A Frame, Electrically Operated, Draw-out Style Air Circuit Breaker was manufactured by ABB & BBC throughout its production. It was originally outfitted with the Micro Power-Shield Trip Unit, however, new trip unit models […]

Read More… from ABB/BBC type LKE-8, 800AF Electrically Operated Air Circuit Breaker.

Siemens-Allis type LA-1600A Manually Operated Air Circuit Breaker.

Part/Catalog Number: LA-1600AOriginal Manufacturer: Siemens – Allis ChalmersProduct Line: LAAmps: 1600A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: AC ProVoltage: 600V MaxInterrupting Capacity: 50kAIC Description: The Siemens-Allis LA-1600A is a 1600A Frame, Manually Operated, Draw-out Style Air Circuit Breaker. It was originally outfitted with a Static Trip series solid state trip unit, however, new trip unit models are […]

Read More… from Siemens-Allis type LA-1600A Manually Operated Air Circuit Breaker.

ITE type KD-A 3000A Solenoid Operated Air Circuit Breaker.

Part/Catalog Number: KD-A 3000AOriginal Manufacturer: ITEProduct Line: K-LineAmps: 3000AOperation: Electrically/Solenoid OperatedMounting: Draw-out Trip Unit: AC-ProVoltage: 600V MaxInterrupting Capacity: 75kAIC Description: The ITE KD-A is a 3000AF, electrically/solenoid operated, draw-out style air circuit breaker. It was originally outfitted with OD style Dashpot overloads, however, new trip unit models are available. Although the unit photographed is an electrically operated […]

Read More… from ITE type KD-A 3000A Solenoid Operated Air Circuit Breaker.

ITE type KC-G-1600 Solenoid Operated Air Circuit Breaker.

Part/Catalog Number: KC-G 1600Original Manufacturer: ITEProduct Line: K-LineAmps: 1600AF Operation: Electrically/Solenoid OperatedMounting: Draw-out Trip Unit: AC-ProVoltage: 600V MaxInterrupting Capacity: 50kAIC Description: The ITE KC-G is a 1600AF, electrically/solenoid operated, draw-out style air circuit breaker. It was originally outfitted with OD-2 Dashpot overloads, however, new trip unit models are available. Although the unit photographed is an electrically operated […]

Read More… from ITE type KC-G-1600 Solenoid Operated Air Circuit Breaker.

ITE type KC-600 600A Solenoid Operated Air Circuit Breaker.

Part/Catalog Number: KC-600Original Manufacturer: ITEProduct Line: KCAmps: 600A Breaker in 1600A Frame SizeOperation: Electrically/Solenoid OperatedMounting: Draw-out Trip Unit: AC-Pro IIVoltage: 600V MaxInterrupting Capacity: 25kAIC Description: The ITE KC-600 is a 600A continuous current, electrically/solenoid operated, draw-out style air circuit breaker – It has the same physical frame size as the KC-G (1600AF). It was originally outfitted with […]

Read More… from ITE type KC-600 600A Solenoid Operated Air Circuit Breaker.

ITE/ABB/BBC/Gould type K-1600S 1600AF Electrically Operated Air Circuit Breaker.

Part/Catalog Number: K-1600SOriginal Manufacturer: ABBProduct Line: K-LineAmps: 1600A FrameOperation: Electrically OperatedMounting: Draw-out Trip Unit: SS Series TripVoltage: 600V MaxInterrupting Capacity: 50kAIC Description: The K-1600S is a 1600A Frame, Manually Operated, Draw-out Style Air Circuit Breaker was manufactured by ITE, BBC, Gould and ABB throughout its original production. It was originally outfitted with solid state trip type SS […]

Read More… from ITE/ABB/BBC/Gould type K-1600S 1600AF Electrically Operated Air Circuit Breaker.

ABB type K-1600M 1600AF Manually Operated Air Circuit Breaker.

Part/Catalog Number: K-1600MOriginal Manufacturer: ABBProduct Line: K-LineAmps: 1600A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: MPS-C Series TripVoltage: 600V MaxInterrupting Capacity: 50kAIC Description: The ABB type K-1600M is a 1600A Frame, Manually Operated, Draw-out Style Air Circuit Breaker. ABB manufactured the K-1600M as a replacement for the original ITE/BBC/Gould type K-1600 with an upgraded solid state trip device […]

Read More… from ABB type K-1600M 1600AF Manually Operated Air Circuit Breaker.

Eaton / Cutler Hammer type DST-2-15-VR-500 2000A Vacuum Replacement Circuit Breaker

Part/Catalog Number: DST-2-15-VR-500 2000AOriginal Manufacturer: Cutler Hammer / EatonProduct Line: DST-2-15-VR / DST-2Amps: 1200A FrameOperation: Electrically OperatedMounting: Draw-out Voltage: 15kV MaxInterrupting Capacity: 500mVA Description: The DST-2-15-VR-500 2000A vacuum circuit breaker was designed by Eaton / Cutler Hammer to directly replace the FPE/Federal Pacific type DST-2-15-500 2000A Air circuit breaker without the need for any modifications to the […]

Read More… from Eaton / Cutler Hammer type DST-2-15-VR-500 2000A Vacuum Replacement Circuit Breaker

Eaton/Cutler Hammer type DSII-608 800AF Manually Operated Air Circuit Breaker.

Part/Catalog Number: DSII-608Original Manufacturer: Eaton / Cutler HammerProduct Line: DSIIAmps: 800A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: Digitrip LIGVoltage: 600V MaxInterrupting Capacity: 65kAIC Description: The Eaton/ Cutler Hammer type DSII-608 is an 800A Frame, Manually Operated, Draw-out Style Air Circuit Breaker. It was originally outfitted with a Digitrip series solid state trip unit, however, new trip unit […]

Read More… from Eaton/Cutler Hammer type DSII-608 800AF Manually Operated Air Circuit Breaker.

Westinghouse/Cutler Hammer DS-632 3200AF Manually Operated Air Circuit Breaker.

Part/Catalog Number: DS-632Original Manufacturer: Westinghouse / Cutler HammerProduct Line: DSAmps: 3200A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: Amptector I-A LSIGVoltage: 600V MaxInterrupting Capacity: 65kAIC Description: The Westinghouse / Cutler Hammer type DS-632 is a 3200A Frame, Manually Operated, Draw-out Style Air Circuit Breaker. It was originally outfitted with an Amptector solid state trip unit, however, new trip […]

Read More… from Westinghouse/Cutler Hammer DS-632 3200AF Manually Operated Air Circuit Breaker.