Cluster Assembly for FPE type FP-75 and FM-100 3000A Breakers.

Manufacturer: FPE Federal PacificPart Number: 1151B1024Breaker Type: FP-75 & FM-100 3000AMP Breakers Description: The FPE 1151B1024 finger cluster assembly is common to all FP-75 3000AF Breakers as well as the fusematic FM-100 3000A Breaker. Referred to as “cluster assembly” in Instruction Manual IN-810.6. Qty. 6 are required for the FP-75 3000AF Breaker and Qty. 12 […]

Read More… from Cluster Assembly for FPE type FP-75 and FM-100 3000A Breakers.

FPE/Federal Pacific 115VAC/125VDC Charging Motor for FP Breakers

Manufacturer: FPE Federal PacificPart Number: 162-004, Motor 14976Breaker Type: FP-25, FP-50, FP-75, FP-100, FM-25, FM-50 Description: The FPE 115VAC/125VDC Spring Charging Motor is used to charge all Stored Energy Mechanisms in the FP Low Voltage Breaker and FM Fusematic Breaker lines. Referred to as motor #14976 in Instruction Manual IN-810.6 – it is also referenced […]

Read More… from FPE/Federal Pacific 115VAC/125VDC Charging Motor for FP Breakers

GTE Sylvania type SSPB-1600 Electrically Operated Air Circuit Breaker.

Part/Catalog Number: SSPB – 1600 EO/DOOriginal Manufacturer: GTE – SylvaniaProduct Line: SSPBAmps: 1600A FrameOperation: Electrically OperatedMounting: Draw-out Trip Unit: Sylvania RZ.2 Voltage: 600V MaxInterrupting Capacity: 50kAIC Description: The GTE-Sylvania SSPB-1600 is a 1600A Frame, Electrically Operated, Draw-out Style Air Circuit Breaker. It was originally outfitted with the Sylvania RZ series solid state relay, however, new trip unit […]

Read More… from GTE Sylvania type SSPB-1600 Electrically Operated Air Circuit Breaker.

Cutler Hammer-Eaton type MDS-608 Electrically Operated Insulated Case Circuit Breaker.

Part/Catalog Number: MDS-608Original Manufacturer: Eaton / Cutler HammerProduct Line: Magnum DSAmps: 800A FrameOperation: Electrically OperatedMounting: Draw-out Trip Unit: Digitrip 1150+ LSIGVoltage: 600V MaxInterrupting Capacity: 65kAIC Description: The Eaton MDS-608 is an 800A Frame, Electrically Operated, Draw-out Style Insulated Case Circuit Breaker. It was originally outfitted with the Digitrip 520, 520M, 1150 or 1150+ trip unit, however, new […]

Read More… from Cutler Hammer-Eaton type MDS-608 Electrically Operated Insulated Case Circuit Breaker.

General Electric AKU-2A-50 Manually Operated Fused Air Circuit Breaker.

Part/Catalog Number: AKU-2A-50Original Manufacturer: General Electric (GE)Product Line: AKUAmps: 1600A FrameOperation: Manually OperatedMounting: Draw-out Trip Unit: AC-ProVoltage: 600V MaxInterrupting Capacity: 200kAIC / FusedFuse Size: 2000A Description: The General Electric AKU-2A-50 is a 1600A Frame, Manually Operated, Draw-out Style, Fused Air Circuit Breaker. It was originally outfitted with EC-1 or EC-2 series electro-mechanical overloads, however, new trip unit […]

Read More… from General Electric AKU-2A-50 Manually Operated Fused Air Circuit Breaker.

GE 108C9667G2 Open Fuse Lockout Assembly for AK/AKR

Manufacturer: General ElectricPart Number: 121C2870G2, 425D409G1 425D370G1 Breaker Type: AKU-25, AKU-50, AKU-75, AKU-100, AKRU-30, AKRU-50, AKRU-75, AKRU-100 Description: The General Electric 121C2870G2, 425D409G1, and 425D370G1 refer to the open fuse lockout (OFLO) assembly for the GE type AK & AKR product line. This assembly can be used on all AKU and AKRU fused air circuit […]

Read More… from GE 108C9667G2 Open Fuse Lockout Assembly for AK/AKR

Westinghouse 792A086G01 Secondary Disconnect for DH/DHP

Manufacturer: WestinghousePart Number: 792A086G01 Breaker Type: All DH and DHP Breaker Frames. Description: The Westinghouse 792A086G01 is a breaker side Secondary Contact (Includes Block & Guide Pins) for the entire Westinghouse type DH & type DHP Breaker Product Line. Often referred to as a secondary disconnect assembly, the Westinghouse parts book refers to it as […]

Read More… from Westinghouse 792A086G01 Secondary Disconnect for DH/DHP

General Electric 0282A2725G002 1200A Primary Disconnect

Manufacturer: General ElectricPart Number: 0282A2725G002Breaker Type: All PowerVac VB/VB1, ML-17/ML-18 Mech, 1200A Description: The GE 0282A2725G002 Primary Disconnect is a breaker side 1200A primary disconnect or finger cluster assembly for the GE PowerVac Vacuum Circuit Breaker. These finger clusters are utilized on all 1200A PowerVac VB & VB1 Breaker frames. Found in renewal parts book […]

Read More… from General Electric 0282A2725G002 1200A Primary Disconnect

Westinghouse 18B1225G09 DB/DBF Secondary Contact (4P)

Manufacturer: WestinghousePart Number: 18B1225G09Breaker Type: DB-15, DB-25, DB-50, DB-75, DB-100, DBF-6, DBF-16, DBF-40 Description: The Westinghouse 18B1225G09 Secondary Contact (4P) is a breaker side secondary disconnect. The secondary contact is utilized on all DB & DB Breaker frames ranging from 225A-4000A frames. The 18B1225G09 is referred to as the “Moving Secondary Contact (4P)” for the […]

Read More… from Westinghouse 18B1225G09 DB/DBF Secondary Contact (4P)

Westinghouse 679C711G08 DB/DBF Finger Clusters

Manufacturer: WestinghousePart Number: 679C711G08Breaker Type: DB-50, DB-75, DB-100, DBF-16, DBF-40 Description: The Westinghouse 679C711G08 Finger Clusters are used on 1600A-4000A Single-Position & 3-Position Air Circuit Breaker Frames with the following quantities required per breaker: DB-50 – 6 Required Per Breaker, DB-75 – 12 Required Per Breaker, DB-100 – 12 Required Per Breaker, DBF-16 – 6 […]

Read More… from Westinghouse 679C711G08 DB/DBF Finger Clusters